{"id":1032,"date":"2014-01-30T13:19:00","date_gmt":"2014-01-30T05:19:00","guid":{"rendered":"http:\/\/www.eumz.com\/?p=1032"},"modified":"2014-01-30T13:19:00","modified_gmt":"2014-01-30T05:19:00","slug":"dell-raid%e6%8e%a7%e5%88%b6%e5%8d%a1%ef%bc%88perc%ef%bc%896%e3%80%817%e3%80%818%e7%b3%bb%e5%88%97%e4%bb%8b%e7%bb%8d","status":"publish","type":"post","link":"https:\/\/www.wxcn.com\/?p=1032","title":{"rendered":"Dell raid\u63a7\u5236\u5361\uff08perc\uff096\u30017\u30018\u7cfb\u5217\u4ecb\u7ecd"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td colspan=\"10\"><strong>PowerEdge RAID Controller (PERC) Series 8 Family<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Model\u00a0<\/strong><\/td>\n<td><strong>Interface Support<\/strong><\/td>\n<td><strong>PCI Support<\/strong><\/td>\n<td><strong>SAS Connectors\u00a0<\/strong><\/td>\n<td><strong>Cache Memory Size<br \/>\n<\/strong><\/td>\n<td><strong>Write Back Cache\u00a0<\/strong><\/td>\n<td><strong>RAID Levels\u00a0<\/strong><\/td>\n<td><strong>Max Drive Support\u00a0<\/strong><\/td>\n<td colspan=\"2\"><strong>RAID Support<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H810 Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 External<\/td>\n<td>1GB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>192<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H710P Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>1GB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong><strong>PERC H710P Mini Mono<\/strong><\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>1GB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H710P Mini Blade<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>1GB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H710 Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>512MB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H710 Mini Mono<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>512MB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H710 Mini Blade<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>512MB NV<\/td>\n<td>Flash Backed Cache<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H310 Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,10,50<\/td>\n<td>16, Non-RAID 32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H310 Mini Mono<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,10,50<\/td>\n<td>16, Non-RAID 32<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H310 Mini Blade<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,10,50<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>S110 Software RAID<\/strong><\/td>\n<td>3Gb\/s SATA<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,10<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Software RAID &#8211; Windows Only<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H310 Mini Blade<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>Express 2.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,10,50<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\"><strong>PowerEdge RAID Controller (PERC) Series 6 &amp; 7 Family<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0Model<\/strong><\/td>\n<td><strong>Interface Support<\/strong><\/td>\n<td><strong>PCI Support<\/strong><\/td>\n<td><strong>SAS Connectors<\/strong><\/td>\n<td><strong>Cache Memory Size<\/strong><\/td>\n<td><strong>Write Back Cache<\/strong><\/td>\n<td><strong>RAID Levels<\/strong><\/td>\n<td><strong>Max Drive Support<\/strong><\/td>\n<td colspan=\"2\"><strong>RAID Support<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H800 Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 External<\/td>\n<td>2MB, 512MB NV, 1GB NV<\/td>\n<td>Yes (TBBU)<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>192<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H700 Integrated \/ Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>512MB, 512MB NV, 1GB NV<\/td>\n<td>Yes (BBU)<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>16<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H700 Modular<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>512MB<\/td>\n<td>Yes (BBU)<\/td>\n<td>0,1,5,6,10<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H200 Integrated \/ Adapter<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,10 Supports non-RAID<\/td>\n<td>16<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC H200 Modular<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,10 Supports non-RAID<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>6Gbps SAS HBA<\/strong><\/td>\n<td>6Gb\/s SAS<\/td>\n<td>PCI-Express 2.0<\/td>\n<td>2&#215;4 External<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td colspan=\"2\">HBA Hardware<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC 6\/E Adapter<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>2&#215;4 External<\/td>\n<td>512MB, 256 MB<\/td>\n<td>Yes (TBBU)<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>144<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC 6\/I Integrated \/ Adapter<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>256MB<\/td>\n<td>Yes (BBU)<\/td>\n<td>0,1,5,6,10,50,60<\/td>\n<td>16<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC 6\/I Modular<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>256MB<\/td>\n<td>Yes (BBU)<\/td>\n<td>0,1,5,6,10<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>CERC 6\/I Modular<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>128MB<\/td>\n<td>&#8211;<\/td>\n<td>0,1,5,6,10<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>SAS 6\/iR Integrated \/ Adapter<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1<\/td>\n<td>8<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>SAS 6\/iR Modular<\/strong><\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>1&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Hardware RAID<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC S300<\/strong>Windows only OS<\/td>\n<td>3Gb\/s SAS<\/td>\n<td>PCI-Express 1.0<\/td>\n<td>2&#215;4 Internal<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,10,5<\/td>\n<td>8<\/td>\n<td colspan=\"2\">Software RAID on HBA<\/td>\n<\/tr>\n<tr>\n<td><strong>PERC S100<\/strong>Windows only OS<\/td>\n<td>3Gb\/s SATA<\/td>\n<td>&#8211;<\/td>\n<td>4 cabled SATA<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>0,1,10,5<\/td>\n<td>4<\/td>\n<td colspan=\"2\">Software RAID on SATA Chipset<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>PowerEdge RAID Controller (PERC) Series 8 Family Model\u00a0 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[82,139,140,220,233,588,589],"class_list":["post-1032","post","type-post","status-publish","format-standard","hentry","category-pcserver","tag-dell","tag-h710","tag-h710p","tag-perc","tag-raid","tag-588","tag-589"],"_links":{"self":[{"href":"https:\/\/www.wxcn.com\/index.php?rest_route=\/wp\/v2\/posts\/1032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wxcn.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wxcn.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wxcn.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wxcn.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1032"}],"version-history":[{"count":0,"href":"https:\/\/www.wxcn.com\/index.php?rest_route=\/wp\/v2\/posts\/1032\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.wxcn.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wxcn.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wxcn.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}